Server administration
Configure rules at /avenex/admin on your server's HTTP address. Keep access
credentials private.
Saving and enabling rules
Save applies and stores your selections. Reload to confirm the saved values. Import/export transfers settings, not served penalties or race results. Back up settings before importing.
A field's server control has different effects: - For an on/off setting, disabling its server control forces it off. - For a penalty-ladder threshold, disabling its control disables that sanction. - For other numeric selectors, disabling the control allows the client's local value. This does not mean zero. Keep scoring controls enabled for consistent league rules.
A field's Reset restores its default. The separate race-state reset clears session points and sanction memory; it is not a configuration reset. Changes do not recalculate past scores or penalties. The reaction and hold values for a cut apply when that cut starts.
Choosing a setup
Configure contact points first (defaults 1/2/3), then enable the ladder levels and thresholds you want. Set pit service in Avenex enforcement, not in legacy native controls. Enable post-race processing to apply accumulated penalty seconds to final results.
For cuts, choose a count limit, service sanction, reaction margin, maximum throttle, control duration and time per violation. Example: 1 s margin, 20% throttle, 3 s control, +5 s. Excess throttle during the margin is allowed; the first excess during control adds +5 s immediately.
For VSC/FCY, configure a speed limit and slowdown countdown separately from the throttle rule for cuts. Do not rely on disabled cards.
See penalty behavior, incident scoring and versions.
Settings
Defaults below are factory values, not necessarily your saved values.
Penalty ladder
Contact points
Points per normal contact. Minimal contacts remain zero; changes apply only to new incidents.
- Default: 1 points.
- Choices: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10.
Heavy contact points
Points per heavy contact; does not change severity detection.
- Default: 2 points.
- Choices: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10.
Spin contact points
Points per contact with detected spin; a spin without contact is not an incident.
- Default: 3 points.
- Choices: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10.
Incident ladder
Apply official penalties from accumulated incident points.
- Default: false.
- Choices: Enabled, Disabled.
Warning at
Incident points needed before issuing a warning.
- Default: 8 points.
- Choices: 2, 4, 6, 8, 10, 12, 16.
Time penalty at
Incident points needed before adding post-race time.
- Default: 12 points.
- Choices: 2, 4, 6, 8, 10, 12, 16, 24.
Drive-through at
Incident points needed before issuing a drive-through.
- Default: 16 points.
- Choices: 2, 4, 6, 8, 10, 12, 16, 20, 24.
Stop and go at
Incident points needed before issuing a stop-and-go.
- Default: 20 points.
- Choices: 2, 4, 6, 8, 10, 12, 16, 20, 24, 30.
Disqualify at
Incident points needed before disqualification.
- Default: 30 points.
- Choices: 2, 4, 6, 8, 10, 16, 20, 24, 30, 40, 60.
Track cuts
Track-cut rule
Count track-limit cuts independently from incident points.
- Default: false.
- Choices: Enabled, Disabled.
Cut limit
Count four-wheel excursions up to this limit, then pause cuts and throttle penalties until the sanction is served.
- Default: 3 cuts.
- Choices: 1, 2, 3, 4, 5, 6, 8, 10.
Reaction margin
Time after leaving the track to release the throttle. Throttle monitoring starts after this margin; the cut still counts.
- Default: 1000 ms.
- Choices: 0, 500, 1000, 1500, 2000, 3000, 5000.
Maximum throttle
Maximum throttle allowed during the hold period, after the reaction margin.
- Default: 10 %.
- Choices: 0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100.
Throttle hold duration
Keep throttle at or below the maximum for this entire period after the reaction margin, even after rejoining.
- Default: 3 s.
- Choices: 1, 2, 3, 4, 5, 10, 15.
Throttle violation penalty
After the reaction margin, immediately add these seconds on the first throttle excess, once per cut. Monitoring stops at the cut limit.
- Default: 5 s.
- Choices: 1, 2, 3, 5, 10, 15, 20, 30, 60.
Cut sanction
Official penalty sent when the cut limit is reached.
- Default: DRIVE_THROUGH.
- Choices: Drive-through, Stop and go, Disqualification.
Blue flags
This card is unavailable for configuring rules in this edition.
Blue-flag rule
Require yielding to the specific faster car behind.
- Default: false.
- Choices: Enabled, Disabled.
Yield window
Seconds before penalizing a missed blue flag.
- Default: 10 s.
- Choices: 5, 10, 15, 20.
Behind distance
Normalized track distance used to select the target behind.
- Default: 0.18 track.
- Choices: 0.08, 0.12, 0.18, 0.25.
Blue-flag sanction
Official penalty sent if the target is not yielded.
- Default: DRIVE_THROUGH.
- Choices: Drive-through, Stop and go, Disqualification.
Yellow flags
This card is unavailable for configuring rules in this edition.
Yellow-flag rule
Require a speed drop while a caution flag is active.
- Default: false.
- Choices: Enabled, Disabled.
Slow-down window
Time available to reduce speed under yellow.
- Default: 3000 ms.
- Choices: 1000, 2000, 3000, 5000.
Required slow-down
Speed drop needed under yellow.
- Default: 10 km/h.
- Choices: 5, 10, 15, 20.
Yellow sanction
Official penalty sent if the driver does not slow.
- Default: DRIVE_THROUGH.
- Choices: Drive-through, Stop and go, Disqualification.
Virtual safety car
VSC / FCY rule
Enable Avenex virtual safety car and full-course-yellow speed enforcement.
- Default: false.
- Choices: Enabled, Disabled.
Manual VSC active
Deploy or clear VSC from the server admin panel.
- Default: false.
- Choices: Enabled, Disabled.
VSC speed limit
Maximum speed while VSC is active.
- Default: 80 km/h.
- Choices: 40, 50, 60, 80, 100.
Slow-down countdown
Seconds available to slow down after VSC deploys.
- Default: 10 s.
- Choices: 5, 8, 10, 15, 20.
Speed tolerance
Extra km/h allowed over the VSC limit.
- Default: 3 km/h.
- Choices: 0, 2, 3, 5, 10.
Speeding debounce
Time above the VSC limit before issuing a penalty.
- Default: 500 ms.
- Choices: 250, 500, 1000, 2000.
VSC speeding sanction
Penalty sent if a driver exceeds the VSC limit after the countdown.
- Default: DRIVE_THROUGH.
- Choices: Drive-through, Stop and go, Disqualification.
Auto-deploy
Deploy VSC automatically from heavy incidents, multi-car clusters, or stopped cars.
- Default: false.
- Choices: Enabled, Disabled.
Cluster contacts
Nearby contact count needed to auto-deploy VSC.
- Default: 2 contacts.
- Choices: 2, 3, 4.
Cluster window
Time window used to group multi-car incidents.
- Default: 3000 ms.
- Choices: 1500, 2500, 3000, 5000.
Cluster distance
Maximum distance between contacts in the same VSC cluster.
- Default: 50 m.
- Choices: 25, 50, 75, 100.
Heavy-contact deploy
Impact speed that deploys VSC immediately.
- Default: 35 km/h.
- Choices: 25, 35, 45, 60.
Stopped speed
Speed treated as stopped for a post-contact car on track.
- Default: 5 km/h.
- Choices: 2, 5, 8, 10.
Stopped duration
How long a recently contacted car must remain stopped on track before VSC deploys.
- Default: 5000 ms.
- Choices: 3000, 5000, 8000, 10000.
Stopped contact window
Maximum age of the previous contact used to consider a stopped car hazardous.
- Default: 15000 ms.
- Choices: 10000, 15000, 20000, 30000.
Auto-clear delay
Seconds without a new hazard before auto VSC clears.
- Default: 20 s.
- Choices: 10, 20, 30, 45, 60.
Pit speeding
This card is unavailable for configuring rules in this edition.
Pit-speeding rule
Detect pit-lane speeding from client telemetry.
- Default: false.
- Choices: Enabled, Disabled.
Tolerance
Speed allowed over the pit limit before enforcement.
- Default: 2 km/h.
- Choices: 0, 2, 5, 10.
Debounce
Time over the limit before a penalty is issued.
- Default: 250 ms.
- Choices: 100, 250, 500, 1000.
Pit-speeding sanction
Official penalty sent for pit-lane speeding.
- Default: DRIVE_THROUGH.
- Choices: Drive-through, Stop and go, Disqualification.
Avenex enforcement
Avenex DT/S&G service
Track drive-through and stop-and-go service in Avenex instead of native AC/CSP HUD.
- Default: true.
- Choices: Enabled, Disabled.
DT deadline
Current-lap based deadline before missed DT escalates to disqualification.
- Default: 1 laps.
- Choices: 1, 2, 3.
DT speed tolerance
Extra km/h allowed over the pit limit while serving a drive-through.
- Default: 2 km/h.
- Choices: 0, 2, 5, 10.
Pit limit fallback
Fallback pit speed limit if the client cannot read the session value.
- Default: 80 km/h.
- Choices: 30, 50, 60, 80.
S&G deadline
Current-lap based deadline before missed stop-and-go escalates to disqualification.
- Default: 1 laps.
- Choices: 1, 2, 3.
S&G hold
Seconds the driver must stay stopped in pit lane.
- Default: 5 s.
- Choices: 3, 5, 10, 15, 30.
Stopped speed
Maximum speed treated as stopped for stop-and-go hold tracking.
- Default: 1 km/h.
- Choices: 0, 1, 2, 5.
Post-race time
Post-race penalties
Add issued penalty seconds to native final race results and the audit report.
- Default: false.
- Choices: Enabled, Disabled.
Seconds per penalty
Seconds issued when the time penalty threshold is reached.
- Default: 1 s.
- Choices: 0, 1, 2, 3, 5, 10.
Native enforcement
The current flow uses native enforcement only for disqualification. Legacy DT and hold selectors do not configure Avenex pit service.
Native enforcement
Enables the native disqualification command. Does not enable native DT or Stop & Go.
- Default: false.
- Choices: Enabled, Disabled.
DT deadline
Legacy setting, with no effect on Avenex DT/Stop & Go service. Use Avenex enforcement.
- Default: 2 laps.
- Choices: 1, 2, 3.
Hold duration
Legacy setting, with no effect on Avenex DT/Stop & Go service. Use Avenex enforcement.
- Default: 5 s.
- Choices: 5, 10, 15, 30.
Server chat messages
Send Avenex penalty chat messages in addition to native HUD.
- Default: true.
- Choices: Enabled, Disabled.
Server overlays
Avenex overlays
Force Avenex overlay channels on or off for connected clients. This server value overrides the client local INI.
- Default: true.
- Choices: Enabled, Disabled.
HUD feedback
This card is unavailable for configuring rules in this edition.
Incident monitor
Show the compact incident monitor.
- Default: true.
- Choices: Enabled, Disabled.
Cut monitor
Show the compact cuts monitor.
- Default: true.
- Choices: Enabled, Disabled.
Race Control Banners
Show Avenex Race Control Banner overlays.
- Default: true.
- Choices: Enabled, Disabled.
Compliance Advisories
Show Avenex Compliance Advisory overlays.
- Default: true.
- Choices: Enabled, Disabled.
Post-race monitor
Show the compact post-race seconds monitor.
- Default: false.
- Choices: Enabled, Disabled.